Fire alarm system

Searching...

    Fire alarm systems are a special type of component; the general guidelines for modeling components apply.

    Fire alarm systems are installed in buildings to detect smoke or fire in order to protect people from fire. The fire alarm system is designed in accordance with TRVB S 123, DIN 14675, and VDE 0833-1/-2, depending on the type of building and regulatory requirements.

    The "Fire Detectors" category includes, for example, the following components:

    • Push-button smoke alarm
    • Smoke detector
    • Strobe light
    • Holding magnet
    • Siren
    • Trigger button
    • Fire department control panel
    • Fire department key safe
    • RAS station
    • Smoke and heat exhaust system actuators

    No fire alarms will be installed during this phase of the project.

    No floor plans are created during this phase of the project; however, a conceptual diagram of the fire alarm system is developed. For more general information on fire protection, see the article on fire and smoke compartment boundaries.

    During this phase, the exact locations of all components of the fire alarm system are defined on the floor plans. The fire detectors are plotted in three dimensions at their exact locations.

    Presentation

    Plan view

    Plan view

    Model representation

    Model representation

    Plan view

    Plan view

    Model representation

    Model representation

    Switzerland Content

    Features

    The characteristics to be defined in this phase should be added in the same way as described in the "Components" section.

    Labeling

    No labels are necessary at this stage; the legend is sufficient here.

    Instructions

    Data is created in the same way as components are created.

    ArchiCAD Content

    Fire alarm systems are not shown in this phase, but are described in the technical report.

    During this phase, the exact locations of all components of the fire alarm system are marked on the floor plan.

    The fire detectors are modeled in three dimensions at their exact locations.

    When installing fire alarms in drop ceilings, it is necessary to provide access panels.

    Presentation

    In this phase, the plans and models remain unchanged from the design phase.

    Feature

    The following characteristics are defined in this phase:

    • Address
    • Loop
    • Control panel

    Labeling

    At this stage, the following information should be added to the labeling:

    • Address
    • Control panel

    Instructions

    In this phase, the creation process remains the same as in the Draft.
    ArchiCAD Content

    upgrade.png